|
|
|
| |
|
BLMA |
|
| 0,8 ... 2,5 GHz |
| Model |
Frequency Range |
Output Power
PN min W |
Gain min / typ dB |
Harmonics 2nd / 3rd dBc |
Line Power
W |
Dimensions (H, D) 19"-System |
Weight
kg |
| BLMA 0825-1 |
0,8 ... 2,5 GHz |
1 |
30 / 32 ? |
20 / 20 |
75 |
3 HU, 350 mm |
11 |
| BLMA 0825-3 |
0,8 ... 2,5 GHz |
3 |
34.8 / 37 ? |
20 / 20 |
75 |
3 HU, 350 mm |
11 |
| BLMA 0825-5 |
0,8 ... 2,5 GHz |
5 |
37 / 39 ? |
20 / 20 |
75 |
3 HU, 350 mm |
12 |
| BLMA 0825-10 |
0,8 ... 2,5 GHz |
10 |
40 / 42 ? |
20 / 20 |
150 |
3 HU, 350 mm |
13 |
| BLMA 0825-20 |
0,8 ... 2,5 GHz |
20 |
43 / 45 ? |
20 / 20 |
250 |
3 HU, 350 mm |
13 |
| BLMA 0825-40 |
0,8 ... 2,5 GHz |
40 |
46 / 48 ? |
20 / 20 |
350 |
3 HU, 630 mm |
18 |
| BLMA 0825-75 |
0,8 ... 2,5 GHz |
75 |
48.8 / 51 ? |
20 / 20 |
600 |
3 HU, 630 mm |
22 |
| BLMA 0825-150 |
0,8 ... 2,5 GHz |
150 |
51.8 / 54 ? |
20 / 20 |
1200 |
3 HU, 630 mm |
26 |
| BLMA 0825-300 |
0,8 ... 2,5 GHz |
300 |
54,8 / 57 ? |
20 / 20 |
2400 |
6 HU, 630 mm |
52 |
| BLMA 0825-500 |
0,8 ... 2,5 GHz |
500 |
57 / 59 ? |
20 / 20 |
5000 |
13 HU, 630 mm |
120 |
| Standard Specifications: |
| Input Power: |
0 dBm (1 mW) max. |
| Overdrive Protection: |
up to +10 dBm for no damage |
| Input Impedance: |
50 Ohm nominal |
| Output Impedance: |
50 Ohm nominal |
| Input VSWR: |
<2:1 typ. |
| Load VSWR: |
2:1 max. for PN -0.5 dB infinite for no damage |
| Spurious (at PN): |
-50 dBc typ. (excluding harmonics) |
| Class of Operation: |
A-linear |
|
General: |
| RF Input: |
N-f (<8 GHz), standard on rear panel SMA-f (8 to 18 GHz), standard on front panel K-f (>18 GHz), standard on front panel |
| RF Output: |
N-f (<8 GHz), standard on rear panel SMA-f (8 to 18 GHz), standard on front panel K-f (>18 GHz), standard on front panel
|
| Mains Supply: |
Line Power: <1000 W 100 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: 1000 ... 3000 W 200 ... 240 V AC ?0% / 47 ... 63 Hz Line Power: >3000 W 3x 400 V AC ?0% / 47 ... 63 Hz |
| Elapsed Time Meter: |
via status display |
| Ambient Temperature: |
0 ... +45 癈 |
| Storage Temperature: |
-20 ... +85 癈 |
| Relative Humidity: |
up to 95% (non-condensing ) |
| Operating Altitude: |
up to 2000 m above sea level |
| Vibration and Shock: |
MIL-STD-810 F |
| Cooling: |
forced air with integral blower, air intake from front air exhaust at rear |
| Options: |
| A) RF Monitor Outputs |
G) Output Isolator |
| B) External Dual Directional Coupler |
H) DC-Supply |
| C) IEEE-488.2 GPIB Remote Control |
I) 3x 200 V AC / 60 Hz |
| D) Front Panel RF-Connectors |
R) RS-232C Remote Control |
| E) Power Indication (digital) |
U) USB Remote Control |
| F) Gain Adjustment |
|
| |
| Specifications are subject to change without notice |
|
|
|
| 我们能为您定制的各种系统的解决方案 |
|
|